Skip to content

How we build

The details that decide how well a system performs and how long it lasts: the mounting, the cables and the batteries.

The right mounting for every roof

Every roof gets the mounting that suits it. Our engineers identify the roof and check its structure, typhoon wind loads included, before choosing one.

  1. 01

    L-feet with tek screws

    When to use

    Corrugated or rib-type metal roofs, the most common on factories, warehouses and newer houses.

  2. 02

    Seam clamps

    When to use

    Standing seam roofs. The clamps grip the seam, so nothing pierces the sheet.

  3. 03

    Roof tile hooks

    When to use

    Clay or concrete tile roofs, common on houses and resorts.

  4. 04

    Ballasted tilted frames

    When to use

    Flat concrete roof decks. Concrete ballast holds the frames down, so nothing is drilled into the slab.

Cables sized to the right ampacity

Undersized cable runs hot, wastes energy and can start a fire. Every cable we lay is sized to the Philippine Electrical Code.

  1. 01

    Full current, with margin

    Sized for the most current the circuit can carry in full sun, with extra margin because solar runs at full output for hours.

  2. 02

    Rated for heat

    Rated up for rooftop heat and for cables run together in one conduit or tray, which warm each other.

  3. 03

    Low voltage drop

    Sized up on long runs, so little power is lost between the panels and the inverter.

  4. 04

    Matched protection

    Fuses and breakers are never rated above what the cable can carry, so they trip before it can overheat.

Battery storage, beyond the label

The kWh on a battery's label does not tell the whole story. These four things decide how much it really gives you, and for how long.

  1. 01

    Usable capacity

    Depth of discharge (DOD)

    A battery is never run completely empty, because that wears it out fast. The share you can actually use is its depth of discharge, and it is always less than the label. We size on what you can use.

  2. 02

    Health over the years

    State of health (SOH)

    Every battery holds a little less each year. State of health is how much it can still store compared with new. We size with that loss in mind, so the battery still covers your needs in its later years.

  3. 03

    Energy lost in and out

    Round-trip efficiency (RTE)

    Some energy is lost every time a battery charges and discharges. Our savings estimates include that loss, so they are not inflated.

  4. 04

    Kept cool, kept safe

    Heat and fire safety

    Batteries age much faster in heat, so we place them out of the sun with proper cooling, and keep the clearances, ventilation and fire detection the maker and the code require.

Cookie settings

Choose which optional cookies this site may use.

Message us

Choose a channel, or copy the details to contact us.

  • info@solteraenergy.ph